Delmhorst-instrument Navigator Manual de usuario

Busca en linea o descarga Manual de usuario para Herramientas Delmhorst-instrument Navigator. Delmhorst Instrument Navigator User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
NAVIGATOR
MOISTURE MAPPING METER
Owner’s Manual
Version 2.1
For Navigator Meters starting with Serial #11212
Delmhorst Instrument Co.
Rev 3
May, 2010
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - NAVIGATOR

NAVIGATOR MOISTURE MAPPING METER Owner’s Manual Version 2.1 For Navigator Meters starting with Serial #11212 Delmhorst Instrument

Pagina 2 - TABLE OF CONTENTS

Copyright  2007, Delmhorst Instrument Co. Page 10 of 28 TO SET THE ALARM IN BASIC SCAN MODE: 1. If you wish to set the alarm to beep after a pre-

Pagina 3 - Page 3 of 28

Copyright  2007, Delmhorst Instrument Co. Page 11 of 28 Settings stored in each particular mode will not be affected by restoring defaults in a dif

Pagina 4 - GENERAL DESCRIPTION/FEATURES

Copyright  2007, Delmhorst Instrument Co. Page 12 of 28 Use the ï ð keys to toggle between residential and commercial. After you have made yo

Pagina 5 - OPERATING INSTRUCTIONS

Copyright  2007, Delmhorst Instrument Co. Page 13 of 28 TO DEFINE ROOM LOCATION AND MATERIAL DESIGNATION: 1. Using the ñ ò keys on the CREATE JOB

Pagina 6 - Page 6 of 28

Copyright  2007, Delmhorst Instrument Co. Page 14 of 28 Note: The default selection is OAK for the floor and SHEETROCK for the wall and ceiling. I

Pagina 7 - METER USE

Copyright  2007, Delmhorst Instrument Co. Page 15 of 28 This screen contains the following information: Job # and ID, current location (LOC), numbe

Pagina 8 - Page 8 of 28

Copyright  2007, Delmhorst Instrument Co. Page 16 of 28 3. The default status of the alarm is “OFF.” Press the SELECT key to turn it on. 4.

Pagina 9 - Page 9 of 28

Copyright  2007, Delmhorst Instrument Co. Page 17 of 28 At any time, you may modify Temperature (T), location (LOC), or switch to SCAN mode (GOTO S

Pagina 10 - Page 10 of 28

Copyright  2007, Delmhorst Instrument Co. Page 18 of 28 Note: Memory deletion and restoring defaults are both irreversible. • EXIT: This menu opt

Pagina 11 - Page 11 of 28

Copyright  2007, Delmhorst Instrument Co. Page 19 of 28 all have ample delays built in to allow the other link components to come online in any seq

Pagina 12 - Page 12 of 28

Copyright  2007, Delmhorst Instrument Co. Page 2 of 28 TABLE OF CONTENTS PAGE GENERAL DESCRIPTION & FEATURES 4 OPERAT

Pagina 13 - Page 13 of 28

Copyright  2007, Delmhorst Instrument Co. Page 20 of 28 • Return to Main Menu: This menu option returns the meter to Main Menu. The meter also re

Pagina 14 - Page 14 of 28

Copyright  2007, Delmhorst Instrument Co. Page 21 of 28 are 10, 20, 30sec. It is recommended that the backlight delay be set to the minimum amount

Pagina 15 - Page 15 of 28

Copyright  2007, Delmhorst Instrument Co. Page 22 of 28 ⇒ Set the meter’s parameters as described previously in the owners’ manual. If the speci

Pagina 16 - Page 16 of 28

Copyright  2007, Delmhorst Instrument Co. Page 23 of 28 will move into a hygroscopic (wood) floor, or build-up pressure under a non-breathing synth

Pagina 17 - MAIN MENU OPTIONS:

Copyright  2007, Delmhorst Instrument Co. Page 24 of 28 TESTING DRYWALL ⇒ Set the meter scale for Sheetrock® as described in the Create/Modify a

Pagina 18 - IR LINK:

Copyright  2007, Delmhorst Instrument Co. Page 25 of 28 CARE OF YOUR METER Ø Store your meter in a clean, dry place. The protective carrying cas

Pagina 19 - SETUP MENU:

Copyright  2007, Delmhorst Instrument Co. Page 26 of 28 SERVICE FOR YOUR METER Ø Before sending in your meter we recommend you give one of our tr

Pagina 20 - Page 20 of 28

Copyright  2007, Delmhorst Instrument Co. Page 27 of 28 WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees the Na

Pagina 21 - Page 21 of 28

Copyright  2007, Delmhorst Instrument Co. Page 28 of 28 APPENDIX A: Room list – Residential Jobs Number Abbreviation Description Page 1 1 LR L

Pagina 22 - Page 22 of 28

Copyright  2007, Delmhorst Instrument Co. Page 3 of 28 TESTING CONCRETE SLABS 23 TESTING INSULATION 24 TESTING DRYWALL 24 CARE OF YOUR

Pagina 23 - Page 23 of 28

Copyright  2007, Delmhorst Instrument Co. Page 4 of 28 GENERAL DESCRIPTION/FEATURES Thank you for your purchase of Delmhorst Instrument Co’s newly

Pagina 24 - Page 24 of 28

Copyright  2007, Delmhorst Instrument Co. Page 5 of 28 OPERATING INSTRUCTIONS -User Guide- This guide provides step-by-step instructions on poweri

Pagina 25 - Page 25 of 28

Copyright  2007, Delmhorst Instrument Co. Page 6 of 28 INSTALLING THE BATTERY: The battery compartment is located on the underside of the case, at

Pagina 26 - Page 26 of 28

Copyright  2007, Delmhorst Instrument Co. Page 7 of 28 TO POWER THE METER ON: To turn the meter on, press and hold the SELECT button for approx. 2

Pagina 27 - Page 27 of 28

Copyright  2007, Delmhorst Instrument Co. Page 8 of 28 3. Use the òkey to highlight the default material (Oak) if you wish to change it to a diffe

Pagina 28 - Page 28 of 28

Copyright  2007, Delmhorst Instrument Co. Page 9 of 28 TO CHANGE THE TEMPERATURE CORRECTION: Navigator defaults to a temperature of 70ºF. As wood

Comentarios a estos manuales